Utility of Cortical Bone Tissue Properties in the Assessment of Fracture Risk
Last checked: Nov 20, 2026Latest source record: Nov 10, 2026 (this record)Source: ClinicalTrials.govMethods & limitations
Status
Active, not recruiting
Enrollment
190
Planned (sponsor's estimate)
Start
Jan 26, 2015
Primary completion
Aug 8, 2028
Study completion Nov 2030
Sponsor
- Lead sponsor
- Beth Israel Deaconess Medical CenterAcademic, hospital or other
- Sponsor type
- Academic, hospital or other
- Collaborators
- Brigham and Women's Hospital
- First posted
- Mar 9, 2017
Design
- Study type
- Interventional
- Phase
- Not applicable (typical for device studies)
- Allocation
- Non randomized
- Model
- Single group
- Masking
- None
- Primary purpose
- Prevention
- FDA-regulated device
- Yes
- Who can join
- All sexes, from 50 years, up to 100 years
- Healthy volunteers
- Yes
Summary
As written by the sponsor on the registry.
The objective of this study is to determine whether a new minimally invasive method for in vivo measurement of cortical bone tissue properties can identify those who are at risk for fragility fractures of the hip and radius. The investigators hypothesis is that women with fragility fractures of the hip and radius have altered cortical bone tissue properties compared to non-fracture controls independent of standard clinical tests, such as bone mineral density (BMD) by dual-energy x-ray absorptiometry (DXA).
Conditions
- Distal Radius Fracture
- Osteoporosis
- Hip Fractures
Interventions
Reference Point IndentationDevice
The "Osteoprobe": Since these first reports of indentation measurements in humans in vivo, a more 'user-friendly' device, the Osteoprobe® has been developed by Active Life Scientific (Santa Barbara, CA) (10). The Osteoprobe®, which we will use in the current study, is smaller than the previous reference point indentation (RPI) instrument and is designed to be used in a hand-held fashion to allow for rapid measurements. The new instrument does not require a reference probe, because the inertia of the instrument keeps it adequately fixed in space during the short time of the indentation impact (\~0.25 milliseconds). The main parameter measured is the distance that the probe further indents into the bone from the reference point. Key components of the Osteoprobe® include an impact generation mechanism, a displacement transducer, and a probe made of hardened stainless steel with a 90 degree conical tip, with a tip diameter of \~375 µm.
Primary outcomes
What the sponsor says the trial is designed to measure.
- Cortical bone tissue properties by reference point indentationTime frame: Day 1
1 more outcomes with a free account
Locations
1 site in 1 country. Site status is shown where the registry gives one.
Beth Israel Deaconess Medical Center
Boston, Massachusetts
Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.