Device Trial Radar · NCT02712515
The Motor Network in Essential Tremor: Mechanisms of Therapy
Last checked: Nov 20, 2026Latest source record: Jan 13, 2026 (this record)Source: ClinicalTrials.govMethods & limitations
Status
Completed
Enrollment
21
Actual
Start
Mar 15, 2016
Primary completion
Oct 13, 2025
Study completion Oct 13, 2025
Sponsor
- Lead sponsor
- University of FloridaAcademic, hospital or other
- Sponsor type
- Academic, hospital or other
- Collaborators
- National Institute of Neurological Disorders and Stroke (NINDS); Medtronic
- First posted
- Mar 18, 2016
Design
- Study type
- Observational
- Who can join
- All sexes, from 21 years
- Healthy volunteers
- No
Summary
As written by the sponsor on the registry.
Essential tremor (ET) is among the most common movement disorders, and is the most prevalent tremor disorder. It is a progressive, degenerative brain disorder that results in increasingly debilitating tremor, and afflicts an estimated 7 million people in the US (2.2% of the population) and estimates from population studies worldwide range from 0.4% to 6.3%. ET is directly linked to progressive functional impairment, social embarrassment, and even depression. Intention (kinetic) tremor of the arms occurs in approximately half of ET patients, and is typically a slow tremor (\~5-10Hz) that occurs at the end of a purposeful movement, and is insidiously progressive over many years. Based on direct and indirect neurophysiological studies, it has been suggested that a pathological synchronous oscillation in a neuronal network involving the ventral intermediate nucleus (Vim) of the thalamus, the premotor (PM), primary motor (M1) cortices, and the cerebellum, may result in the production of ET. In spite of the numerous therapeutic modalities available, 65% of those suffering from upper limb tremor report serious difficulties during their daily lives. Deep brain stimulation (DBS) has emerged as an effective treatment option for those suffering from medically refractory ET. The accepted target for ET DBS therapy is the Vim thalamus. Vim projects to PM, M1, and supplementary motor areas (SMA) and receives afferents from the ipsilateral cerebellum. Moreover, electrophysiological recordings from Vim during stereotactic surgery have identified "tremor cells" that synchronously discharge with oscillatory muscle activity during tremor. Clinical and computational findings indicate that DBS suppresses tremor by masking these "burst driver" inputs to the thalamus. The overall goal is to investigate the neural signatures of tremor generation in the thalamocortical network by recording data during DBS implantation surgery. Investigators will record data from the macroelectrode implanted in the Vim for DBS therapy, and through an additional 6-contact subdural cortical strip that will be placed on the hand motor cortical area temporarily through the same burr hole opened for the implantation of the DBS electrode.
Conditions
- Essential Tremor
- Parkinson's Disease
Interventions
Deep brain stimulation implantation surgeryProcedure
Deep brain stimulation is a neuromodulatory therapy in which electrodes are implanted in deep brain structures. Electrical pulses are delivered through these electrodes to suppress pathological activity that are causing the symptoms of essential tremor or Parkinson's disease.
Ad-Tech Medical Instrumentation Corp. electrodes/subdural stripsDevice
Ad-Tech Medical Instrumentation Corp. electrodes are intraoperative monitoring subdural strips will be placed on the surface of the cortex (non-penetrating).
FHC Guideline 4000+ system and/or Medtronic RC+SDevice
Brain signals will be recorded using the clinical Participants in this group with Parkinson's disease will be undergoing deep brain stimulation implantation surgery as part of the standard of care. In addition, the Ad-Tech Medical Instrumentation Corp. device will be used to test responses with wireless sensors placed on the participant's arms, which can record EMG activity. Brain signals will be recorded using the clinical FHC Guideline 4000+ system and/or Medtronic RC+S devices, which are capable of recording during stimulation.
Primary outcomes
What the sponsor says the trial is designed to measure.
- Brain signals between the groupsTime frame: intraoperative
Locations
1 site in 1 country. Site status is shown where the registry gives one.
University of Florida
Gainesville, Florida
Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.