Device Trial Radar · NCT02482493
All Polyethylene Versus Metal Backed Tibial Components in Knee Replacement
Last checked: Nov 20, 2026Latest source record: Nov 19, 2026 (this record)Source: ClinicalTrials.govMethods & limitations
Status
Terminated
Enrollment
14
Actual
Start
Jan 2017
Primary completion
Oct 2026
Study completion Oct 2026
Sponsor
- Lead sponsor
- Maidstone & Tunbridge Wells NHS TrustAcademic, hospital or other
- Sponsor type
- Academic, hospital or other
- First posted
- Jun 26, 2015
Design
- Study type
- Interventional
- Phase
- Not applicable (typical for device studies)
- Allocation
- Randomized
- Model
- Parallel
- Masking
- Single (outcomes assessor)
- Primary purpose
- Treatment
- FDA-regulated device
- No
- Who can join
- All sexes, from 75 years
- Healthy volunteers
- Yes
Summary
As written by the sponsor on the registry.
Total knee arthroplasty (TKA) is one of the most commonly performed orthopaedic procedures. Approximately 84,000 knee replacement procedures were recorded in the UK in 2012. The main goal of TKA is to relieve the disabling pain of arthritic disease. Patient satisfaction following TKA is related to quick recovery and return to daily activities. This can be dependent on the design of the implant used in the knee. Improvements in implant design and surgical technique mean many modern designs offer implant survival rates beyond 10 - 15 years. As cost pressure increases in the NHS the unit cost of implants is now being scrutinised, particularly with regard to cost effectiveness. The Press-Fit Condylar (PFC) Sigma implant can be used with either a conventional metal backed or alternatively an all polyethylene tibial component (part fitted to the shin bone), the latter considerably cheaper to manufacture. Four small prospective randomised trials and one large regional registry study with long follow up support the safe use of all polyethylene tibial components in TKA. The investigators will therefore undertake a prospective randomised controlled trial comparing the results of all polyethylene tibial components with those of conventional metal backed tibial components in patients aged 75 or over, comparing both clinical outcome and radiological survivorship. The type of knee replacement used for each patient (metal-backed or polyethylene) will be chosen at random once a patient has agreed to take part in the study. Data will be collected by means of follow-up appointments and questionnaires and clinical tests both before the operation 1 year, 2 years and 5 years postoperatively. This will allow us to see how both types of knee replacement perform over time and if one performs better than the other in terms of patients movement, pain and functional activities.
Conditions
- Osteoarthritis, Knee
Interventions
Sigma PFCDevice
patients will receive either an all polyethylene tibial component or a metal- backed component
Primary outcomes
What the sponsor says the trial is designed to measure.
- American Knee Society ScoreTime frame: 5 year outcomes
Locations
1 site in 1 country. Site status is shown where the registry gives one.
Trauma & Orthopaedic Dept, Tunbridge Wells Hospital
Pembury, Kent, United Kingdom
Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.