All In MedTech

Device Trial Radar · NCT02423993

Education Effectiveness for Type 1 Diabetes Mellitus on Insulin Pump Therapy

Efficiency Assessment of the Structured Education Program for Type 1 Diabetes Patients on Insulin Pump Therapy

Last checked: Nov 20, 2026Latest source record: Jan 11, 2016 (this record)Source: ClinicalTrials.govMethods & limitations

CompletedResults posted on the registry

Status

Completed

Enrollment

77

Actual

Start

Oct 2009

Primary completion

Oct 2012

Study completion Feb 2013

Sponsor

Lead sponsor
Endocrinology Research Centre, MoscowGovernment (non-federal)
Sponsor type
Government (non-federal)
First posted
Apr 22, 2015

More device trials from this sponsor

Design

Study type
Interventional
Phase
Not applicable (typical for device studies)
Allocation
Randomized
Model
Parallel
Masking
None
Primary purpose
Treatment
Who can join
All sexes, from 18 years, up to 65 years
Healthy volunteers
No

Summary

As written by the sponsor on the registry.

The purpose of this study is to assess the effectiveness of structured group education on glycemic control and Quality of Life (QoL) among users of continuous subcutaneous insulin infusions (CSII).

Conditions

  • Diabetes Mellitus, Type 1

Interventions

  • Education by structured programmeBehavioral

    Thе structured programme was developed in Endocrinology Research Centre. It is based on the following principles: education in group setting, using structured program; intensive insulin treatment using insulin pumps; self-adjustment of insulin dose and pump settings; intensive self-monitoring of blood glucose, including continuous glucose monitoring in real-time ("CGM-RT"); flexible physical activities and meals regimen (liberal diet, based on carbohydrates account using bread units; possible shifts of meals schedule and volume supported by appropriate treatment adjustment). Duration of education course - 8 days (35-37 hours); planned group volume is 7-10 patients.

  • CSIIDevice

    The intensified insulin therapy by means of continuous subcutaneous insulin infusion will be provide by Medtronic insulin pumps: Paradigm MMT-712/715, Paradigm Real-Time MMT-722, Paradigm VEO MMT-754.

  • CGM-RTDevice

    Continuous glucose monitoring ("CGM") will be provide by means of Paradigm Real-Time MMT-722 and Paradigm VEO MMT-754 Medtronic sensor-augmented insulin pumps. For monitoring the Sof-Sensor and MiniLink transmitter (Medtronic) will be use. Each sensor will be use for 6 days. CGM will be use for self-monitoring of blood glucose on permanent basis (more than 6 days per week) within 4 month.

  • Screening for ComplicationsProcedure

    To assess diabetic retinopathy a fundoscopy will be held. Diabetic nephropathy will be assessed by microalbuminuria screening, serum creatinine evaluation and calculation of CKD-EPI glomerular filtration rate. Diabetic neuropathy will be assessed by all kinds of sensitivity evaluation (vibrating, tactile, temperature).

  • Glycaemic control assessmentProcedure

    Glycemic control effectiveness changes will be assessed by measure of glycated hemoglobin (HbA1c). The frequency of blood glucose self-monitoring will be estimated by patient's diaries evaluation, individual glucometer data evaluation and insulin pump reports. Bolus calculator use and hypoglycemia nonsevere frequency will be assessed by reports received from insulin pumps.

  • QoL assessmentProcedure

    For Quality of Life ("QoL") assessment will be used the following validated questionnaires (in Russian): 1. The Medical Outcomes Study 36-Item Short Form Health Survey - SF-36. 2. The Audit of the Diabetes-Dependent Quality of Life - ADDQoL (С. Bradley et al, 1999, adjusted by Starostina E.G., 2003).

  • Knowledge assessmentProcedure

    For the knowledge assessment of disease management the standard Questionnaire for patients with type 1 diabetes will be used. Maximum score equals 37 grades; the satisfactory level of knowledge is scored 27.

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. HbA1cTime frame: 4 month after CSII initiation

Locations

No sites are listed on the registry yet.

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.