COPD AND ASSESSMENT OF RADIOLABELED AEROSOL DURING NONINVASIVE VENTILATION

IN VIVO ASSESSMENT OF RADIOLABELED AEROSOL DURING NONINVASIVE VENTILATION IN STABLE COPD: A RANDOMIZED CROSSOVER CLINICAL TRIAL

Last checked: Nov 20, 2026Latest source record: Sep 25, 2014 (this record)Source: ClinicalTrials.govMethods & limitations

Completed

Status

Completed

Enrollment

9

Actual

Start

Jan 2013

Primary completion

Jan 2013

Study completion Mar 2013

Sponsor

Lead sponsor
Daniella Cunha BrandaoAcademic, hospital or other
Sponsor type
Academic, hospital or other
Collaborators
Universidade Federal de Pernambuco
First posted
Sep 25, 2014

More device trials from this sponsor

Design

Study type
Interventional
Phase
Not applicable (typical for device studies)
Allocation
Randomized
Model
Crossover
Masking
None
Primary purpose
Treatment
Who can join
All sexes, from 18 years, up to 60 years
Healthy volunteers
No

Summary

As written by the sponsor on the registry.

Background: Beneficial effects from noninvasive ventilation (NIV) in acute COPD are well-established, but couple to nebulization is still challenging. Aim: To compare radioaerosol pulmonary deposition and radioaerosol mass balance in the different compartments (pulmonary and extrapulmonary) using vibrating mesh nebulizer (VMN) and jet nebulizer (JN) coupled to NIV.Methods: It was a crossover study involving 9 stable moderate to severe COPD randomly allocated for both phases of the study: Phase 1(NIV+MN,n=9) and phase 2(NIV+JN,n=9). Bronchodilators were delivered during NIV using a facemask (pressures of 12 cmH2O and 5 cmH2O - inspiratory and expiratory, respectively). Radioactivity counts were performed using a gamma camera and regions of interest(ROIs) were delimited. We determine aerosol mass balance from the lungs, upper airways, stomach, nebulizer, circuit, inspiratory and expiratory filters, and mask as a percentage.

Conditions

  • COPD

Interventions

  • Noninvasive ventilationOther

    Bilevel positive pressure (BiPAP Synchrony, Respironics®, Murrysville, Pennsylvania, USA) was applied through face mask (Comfort Full 2, Respironics®, Murrysville, Pennsylvania, USA) attached with straps and pressure adjusted were 12 cmH2O of inspiratory pressure and 5 cmH2O of expiratory pressure after a period of adaptation before beginning the procedure to avoid ventilator-patient asynchrony

  • Jet NebulizerDevice

    Both nebulizers were charged with 2.5 mg of salbutamol and 0.25 mg of ipratropium bromide and 3 mL of saline solution was added to complete 3 Ml. JN (Mist yMax, Air Life, Yorba Linda, USA) was positioned in the circuit using a "T" piece, particle size generation in a 5 µm range (according to the manufacturer information) and flow oxygen tritated at 8 L/min

  • Vibrating Mesh Nebulizer (VMN)Device

    Both nebulizers were charged with 2.5 mg of salbutamol and 0.25 mg of ipratropium bromide and 3 mL of saline solution was added to complete 3 Ml. VMN (Aeroneb Solo, Galway, Ireland) was positioned in the mask using an elbow (Elbow Kit, Respironics®, Murrysville, Pennsylvania, USA), particle size generation in a 1 µm and connected to electrical energy.

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. radioaerosol deposition index into the lungsTime frame: 10 months

Locations

1 site in 1 country. Site status is shown where the registry gives one.

  • Hospital das Clínicas de Pernambuco

    Recife, Pernambuco, Brazil

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.