Device Trial Radar · NCT02247856
COPD AND ASSESSMENT OF RADIOLABELED AEROSOL DURING NONINVASIVE VENTILATION
Last checked: Nov 20, 2026Latest source record: Sep 25, 2014 (this record)Source: ClinicalTrials.govMethods & limitations
Status
Completed
Enrollment
9
Actual
Start
Jan 2013
Primary completion
Jan 2013
Study completion Mar 2013
Sponsor
- Lead sponsor
- Daniella Cunha BrandaoAcademic, hospital or other
- Sponsor type
- Academic, hospital or other
- Collaborators
- Universidade Federal de Pernambuco
- First posted
- Sep 25, 2014
Design
- Study type
- Interventional
- Phase
- Not applicable (typical for device studies)
- Allocation
- Randomized
- Model
- Crossover
- Masking
- None
- Primary purpose
- Treatment
- Who can join
- All sexes, from 18 years, up to 60 years
- Healthy volunteers
- No
Summary
As written by the sponsor on the registry.
Background: Beneficial effects from noninvasive ventilation (NIV) in acute COPD are well-established, but couple to nebulization is still challenging. Aim: To compare radioaerosol pulmonary deposition and radioaerosol mass balance in the different compartments (pulmonary and extrapulmonary) using vibrating mesh nebulizer (VMN) and jet nebulizer (JN) coupled to NIV.Methods: It was a crossover study involving 9 stable moderate to severe COPD randomly allocated for both phases of the study: Phase 1(NIV+MN,n=9) and phase 2(NIV+JN,n=9). Bronchodilators were delivered during NIV using a facemask (pressures of 12 cmH2O and 5 cmH2O - inspiratory and expiratory, respectively). Radioactivity counts were performed using a gamma camera and regions of interest(ROIs) were delimited. We determine aerosol mass balance from the lungs, upper airways, stomach, nebulizer, circuit, inspiratory and expiratory filters, and mask as a percentage.
Conditions
- COPD
Interventions
Noninvasive ventilationOther
Bilevel positive pressure (BiPAP Synchrony, Respironics®, Murrysville, Pennsylvania, USA) was applied through face mask (Comfort Full 2, Respironics®, Murrysville, Pennsylvania, USA) attached with straps and pressure adjusted were 12 cmH2O of inspiratory pressure and 5 cmH2O of expiratory pressure after a period of adaptation before beginning the procedure to avoid ventilator-patient asynchrony
Jet NebulizerDevice
Both nebulizers were charged with 2.5 mg of salbutamol and 0.25 mg of ipratropium bromide and 3 mL of saline solution was added to complete 3 Ml. JN (Mist yMax, Air Life, Yorba Linda, USA) was positioned in the circuit using a "T" piece, particle size generation in a 5 µm range (according to the manufacturer information) and flow oxygen tritated at 8 L/min
Vibrating Mesh Nebulizer (VMN)Device
Both nebulizers were charged with 2.5 mg of salbutamol and 0.25 mg of ipratropium bromide and 3 mL of saline solution was added to complete 3 Ml. VMN (Aeroneb Solo, Galway, Ireland) was positioned in the mask using an elbow (Elbow Kit, Respironics®, Murrysville, Pennsylvania, USA), particle size generation in a 1 µm and connected to electrical energy.
Primary outcomes
What the sponsor says the trial is designed to measure.
- radioaerosol deposition index into the lungsTime frame: 10 months
Locations
1 site in 1 country. Site status is shown where the registry gives one.
Hospital das Clínicas de Pernambuco
Recife, Pernambuco, Brazil
Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.