Device Trial Radar · NCT01964261
Sensory Motor Transformations in Human Cortex
Last checked: Nov 19, 2026Latest source record: Oct 23, 2026 (this record)Source: ClinicalTrials.govMethods & limitations
Status
Active, not recruiting
Enrollment
5
Planned (sponsor's estimate)
Start
Nov 1, 2013
Primary completion
Jul 31, 2028
Study completion Jan 31, 2029
Sponsor
- Lead sponsor
- Richard A. Andersen, PhDAcademic, hospital or other
- Sponsor type
- Academic, hospital or other
- Collaborators
- University of Southern California; Rancho Los Amigos National Rehabilitation Center; University of Colorado, Denver
- First posted
- Oct 17, 2013
Design
- Study type
- Interventional
- Phase
- Not applicable (typical for device studies)
- Allocation
- Not applicable (single group)
- Model
- Single group
- Masking
- None
- Primary purpose
- Basic science
- FDA-regulated device
- Yes
- Who can join
- All sexes, from 22 years, up to 65 years
- Healthy volunteers
- No
Summary
As written by the sponsor on the registry.
This research study is being conducted to develop a brain controlled medical device, called a brain-machine interface. The device will provide people with a spinal cord injury some ability to control an external device such as a computer cursor or robotic limb by using their thoughts along with sensory feedback. Development of a brain-machine interface is very difficult and currently only limited technology exists in this area of neuroscience. Other studies have shown that people with high spinal cord injury still have intact brain areas capable of planning movements and grasps, but are not able to execute the movement plans. The device in this study involves implanting very fine recording electrodes into areas of the brain that are known to create arm movement plans and provide hand grasping information and sense feeling in the hand and fingers. These movement and grasp plans would then normally be sent to other regions of the brain to execute the actual movements. By tying into those pathways and sending the movement plan signals to a computer instead, the investigators can translate the movement plans into actual movements by a computer cursor or robotic limb. A key part of this study is to electrically stimulate the brain by introducing a small amount of electrical current into the electrodes in the sensory area of the brain. This will result in the sensation of touch in the hand and/or fingers. This stimulation to the brain will occur when the robotic limb touches the object, thereby allowing the brain to "feel" what the robotic arm is touching. The device being used in this study is called the Neuroport Array and is surgically implanted in the brain. This device and the implantation procedure are experimental which means that it has not been approved by the Food and Drug Administration (FDA). One Neuroport Array consists of a small grid of electrodes that will be implanted in brain tissue and a small cable that runs from the electrode grid to a small hourglass-shaped pedestal. This pedestal is designed to be attached to the skull and protrude through the scalp to allow for connection with the computer equipment. The top portion of the pedestal has a protective cover that will be in place when the pedestal is not in use. The top of this pedestal and its protective cover will be visible on the outside of the head. Three Neuroport Arrays and pedestals will be implanted in this study so three of these protective covers will be visible outside of the head. It will be possible to cover these exposed portions of the device with a hat or scarf. The investigators hope to learn how safe and effective the Neuroport array plus stimulation is in controlling computer generated images and real world objects, such as a robotic arm, using imagined movements of the arms and hands.
Conditions
- Quadriplegia
Interventions
Neural Prosthetic System 2 (NPS2)Device
The NPS2 comprises 3 NeuroPort Arrays (SIROF). The tip of the electrodes are sputtered iridium oxide film (SIROF). Each array is comprised of 100 1.5 mm microelectrodes organized on a 4mm x 4mm silicon base that is 0.25 mm thick. Each microelectrode is insulated with Parylene-C polymer and is electrically isolated from neighboring electrodes by non-conducting glass. Of the 100 electrodes, 96 are wire bonded using 25m gold alloy insulated wires sealed with a silicone elastomer. The wire bundle is potted to a printed circuit board with epoxy, the circuit board is inserted into the Patient Pedestal (percutaneous connector), and then the Patient Pedestal is filled with silicone elastomer. Two fine platinum reference wires are also attached to the Patient Pedestal. The Patient Pedestal is 19 mm wide at the skin interface.
Primary outcomes
What the sponsor says the trial is designed to measure.
- Patient control over the end effector (virtual or physical)Time frame: Nine years after array implantation
- Absence of infection or irritationTime frame: Nine years after array implantation
Locations
4 sites in 1 country. Site status is shown where the registry gives one.
Rancho Los Amigos National Rehabilitation Center
Downey, California
University of Southern California
Los Angeles, California
Richard Andersen
Pasadena, California
1 more study sites with a free account
Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.