All In MedTech

Device Trial Radar · NCT00949221

Study of Insulin Therapy Augmented by Real Time Sensor IN Type 1 Children and Adolescents (START-IN!)

Evaluation of Long-term Efficacy of 2 Strategies of Real Time Continuous Glucose Monitoring, Compared to Self BG-monitoring in Children and Adolescent With Type 1 Diabetes: a Randomized, Multicenter, Open Trial

Last checked: Nov 20, 2026Latest source record: Feb 6, 2023 (this record)Source: ClinicalTrials.govMethods & limitations

CompletedPivotal-lookingRandomized with 150 participants. This is a heuristic, not a regulatory label.

Status

Completed

Enrollment

150

Actual

Start

Sep 2009

Primary completion

Jul 2012

Study completion Jul 2012

Sponsor

Lead sponsor
Assistance Publique - Hôpitaux de ParisAcademic, hospital or other
Sponsor type
Academic, hospital or other
First posted
Jul 30, 2009

More device trials from this sponsor

Design

Study type
Interventional
Phase
Phase 2 / Phase 3
Allocation
Randomized
Model
Parallel
Masking
None
Primary purpose
Treatment
Who can join
All sexes, from 2 years, up to 18 years
Healthy volunteers
No

Summary

As written by the sponsor on the registry.

Glycemic control in children and adolescent with type 1 diabetes remains inadequate, exposing them to the risk of vascular complications in adulthood. One of the limiting factors is the daily number of self measurements of blood glucose required to optimize intensive insulin therapy. Real Time Continuous Glucose Monitoring augmented by alarms (RT CGM) is a recent innovation. A randomized clinical study has shown its efficacy at short term (3 months). However, optimal clinical use of these devices requires rigorous assessment of their effectiveness on glycemic control, tolerance and acceptability in medium and long term. Primary objective: To assess the long-term effectiveness of two strategies of use of RT CGM (continuous or discontinuous) on glycemic control compared to conventional blood glucose self-monitoring (SMBG). Population: Children and adolescents with type 1 diabetes with inadequate glycemic control despite intensive insulin therapy.

Conditions

  • Type 1 Diabetes

Interventions

  • monitor Paradigm 754 VEO, MINILINK Real Time, Medtronic, CEDevice

    * group 1: continuous glucose monitoring for 3 months, then conventional blood glucose self-monitoring for 9 months; * group 2: intensive strategy using continuous glucose monitoring for 12 months; * group 3: intermediate strategy using continuous glucose monitoring for 3 months, then discontinuous use of the device for 9 months (approximately 40% of the time, alternating with conventional blood glucose self-monitoring).

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. Comparison of the effect of 2 strategies of real time continuous glucose monitoring vs conventional SMBG on glycated haemoglobin = HbA1c measured at inclusion, 3, 6, 9, 12 monthsTime frame: 1 year

Locations

1 site in 1 country. Site status is shown where the registry gives one.

  • Hôpital Robert Debré

    Paris, France

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.