All In MedTech

Device Trial Radar · NCT00750191

Placebo-controlled Trial of Transdiscal Radiofrequency Annuloplasty

A Randomized, Placebo-controlled Trial of Transdiscal Radiofrequency Annuloplasty for Treatment of Discogenic Lower Back Pain

Last checked: Nov 20, 2026Latest source record: Jan 8, 2014 (this record)Source: ClinicalTrials.govMethods & limitations

CompletedResults posted on the registry

Status

Completed

Enrollment

64

Actual

Start

Sep 2007

Primary completion

Sep 2012

Study completion Sep 2012

Sponsor

Lead sponsor
Baylis Medical CompanyNot on our public-company list
Sponsor type
Industry
First posted
Sep 10, 2008

More device trials from this sponsor

Design

Study type
Interventional
Phase
Phase 1
Allocation
Randomized
Model
Parallel
Masking
Double (participant, investigator)
Primary purpose
Treatment
Who can join
All sexes, from 18 years
Healthy volunteers
No

Summary

As written by the sponsor on the registry.

Each patient was assigned to one of the two groups: IDB or Sham. On the day of the procedure, an IV was inserted in pre-procedural area and patient transported to the procedure room. The procedure will be completed under fluoroscopy in prone position. Patients were given 1-4 mg of midazolam for relaxation before the procedure and, if needed, 50-100 mcg of fentanyl IV during the procedure. The patients was randomly assigned to treatment or placebo using computer-generated codes maintained in sequentially numbered opaque envelopes. The physician performing procedure was informed of the assignment. In IDB group, guided by the fluoroscopic imaging, two transdiscal probes was positioned in the posterior annulus using a posterolateral, oblique approach. First, two electrically insulated 17G transdiscal introducers was used to gain an access to the disc space. Than, two radiofrequency probes will be positioned through each of the introducers bilaterally to create a bipolar configuration. Placement of the transdiscal probes within the disc annulus will be confirmed using oblique, lateral, and anterior-posterior fluoroscopic images. Sham group had their introducers and electrodes positioned just outside of the disc. This was also be documented using fluoroscopy. Investigator attached the electrodes to inactive heater control device that provide a similar auditory and visual experience for the patient. Patients were therefore remain blinded to actual treatment and physician performing procedure was not involved in patient's follow-up. Patients were awake and communicating with the physician conducting the procedure and if pain in legs were present and increased during the procedure, the heating protocol would be stopped. Following completion of procedure the patient was transferred to recovery and monitored for 45 minutes, then discharged home with instructions. The patients were followed over a period of 12 months.

Conditions

  • Lower Back Pain

Interventions

  • The Transdiscal Radiofrequency AnnuloplastyDevice

    Adjustment in dosage form, frequency and or duration.

  • The Transdiscal Radiofrequency AnnuloplastyDevice

    interventions include adjustment to dosage form,frequency,duration or switching to treatment arm A

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. Physical FunctionTime frame: 6 months

Locations

2 sites in 1 country. Site status is shown where the registry gives one.

  • The Center for Clinical Research

    Winston-Salem, North Carolina

1 more study sites with a free account

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.