Evaluation of Blood Volume and Perceived Pain During Fingerstick Monitoring of Blood Glucose

Evaluation of Blood Volume and Perceived Pain During Fingerstick Monitoring of Blood Glucose When Using Different Currently Marketed Lancing Devices and Lancets

Last checked: Nov 20, 2026Latest source record: Mar 10, 2010 (this record)Source: ClinicalTrials.govMethods & limitations

CompletedResults posted on the registryPivotal-lookingRandomized with 250 participants. This is a heuristic, not a regulatory label.

Status

Completed

Enrollment

250

Actual

Start

Aug 2008

Primary completion

Sep 2008

Study completion Sep 2008

Sponsor

Lead sponsor
Becton, Dickinson and CompanyPublic (BDX)
Sponsor type
Industry
First posted
Aug 26, 2008

More device trials from this sponsor

Design

Study type
Interventional
Phase
Not applicable (typical for device studies)
Allocation
Randomized
Model
Parallel
Masking
Single (participant)
Who can join
All sexes, from 18 years, up to 70 years
Healthy volunteers
No

Summary

As written by the sponsor on the registry.

The procurement of blood for SMBG, usually via a finger stick, is considered by many patients to be the most painful portion of diabetes therapy. This has led to the marketing of smaller gauge lancets, lancing devices with variable depth settings and blood glucose sensors that require less blood for measurement. In this study, two main outcomes were evaluated: The first, which was assessed at Visit 1, was whether specific combinations of lancets and lancing devices would yield sufficient blood volume to allow valid assessment of diabetic subjects' glucose levels. The other outcome, assessed at Visit 2, was the level of pain perceived by subjects during lancing with specific combinations of lancets and lancing devices. During Visit 2, pain assessment was done using a Visual Analog Scale and such that for each lancet/lancing device, the lowest lancing device setting that yielded a valid BG reading for each subject during Visit 1 was used. A third outcome measure, overall comfort with lancing, was also assessed at Visit 2. A total of 5 combinations of lancets and lancing devices were evaluated. These were as follows: * BD/33G = BD Lancet device/BD 33G lancets (BGM measured with the OneTouch® UltraMini™ (BGM) and OneTouch® Ultra® test strips) * OTM/33G =OneTouch® Mini Lancet device / BD 33G lancet (BGM measured with the OneTouch® UltraMini™ (BGM) and OneTouch® Ultra® test strips) * OTM/28G =OneTouch® Mini Lancet device / OneTouch® UltraSoft® 28G Lancet (BGM measured with the OneTouch® UltraMini™ (BGM) and OneTouch® Ultra® test strips) * OTU/28G = OneTouch® UltraSoft® Lancet device/OneTouch® UltraSoft® 28G Lancet (BGM measured with the OneTouch® UltraMini™ (BGM) and OneTouch® Ultra® test strips) * ACC/28G= Accu-Chek® Softclix Lancet device/Accu-Chek® Softclix 28G Lancet (BGM measured with Accu-Chek® Advantage BGM and Accu-Chek® Comfort Curve test strip) After enrollment and qualification, subjects were assigned to one of 4 intervention arms. The arm assignment determined which 3 of the 5 combinations of lancets and lancing devices the subjects would evaluate in Visit 1 (for volume adequacy) and of these 3, which 2 they would evaluate in Visit 2 (pain during lancing). The lancet/lancing device combinations assigned to each arm are shown in the Assigned Interventions Table below.

Conditions

  • Diabetes Mellitus, Type 1
  • Diabetes Mellitus, Type 2

Interventions

  • BD/33GDevice

    BD Lancet device/BD 33G lancets (BGM measured with the OneTouch® UltraMini™ (BGM) and OneTouch® Ultra® test strips)

  • OTM / 33GDevice

    OneTouch® Mini Lancet device / BD 33G lancet (BGM measured with the OneTouch® UltraMini™ (BGM) and OneTouch® Ultra® test strips)

  • OTU/28GDevice

    OneTouch® UltraSoft® Lancet device/OneTouch® UltraSoft® 28G Lancet (BGM measured with the OneTouch® UltraMini™ BGM) and OneTouch® Ultra® test strips)

  • ACC/28GDevice

    Accu-Chek® Softclix Lancet device/Accu-Chek® Softclix 28G Lancet (BGM measured with Accu-Chek® Advantage BGM and Accu-Chek® Comfort Curve test strip)

  • OTM/28GDevice

    OneTouch® Mini Lancet device / OneTouch® UltraSoft® 28G Lancet (BGM measured with the OneTouch® UltraMini™ (BGM) and OneTouch® Ultra® test strips)

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. Blood Sample of Sufficient Volume to Yield a Valid Meter ReadingTime frame: Study Day 1 (Visit 1)
  2. Difference in Lancing Pain for Device Pair at Visit 2. (For Subjects Assigned to Arms A, B, C Only)Time frame: Approximately Day 3 (Visit 2)

Locations

4 sites in 1 country. Site status is shown where the registry gives one.

  • Thomas J. Stephens & Associates

    Colorado Springs, Colorado

  • TKL Research, Inc.

    Carlstadt, New Jersey

  • TKL Research, Inc

    Paramus, New Jersey

1 more study sites with a free account

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.