Device type · JJH
Clinical Sample Concentrator
Last checked: Nov 19, 2026Source: openFDAMethods & limitations
Product code
JJH
Clinical Chemistry
Device class
Class I
FDA decisions since 2015
0
510(k), De Novo and PMA
Adverse event reports
15
Received Nov 1, 2025 to Nov 20, 2026
How FDA classifies it
- Device type
- Clinical Sample Concentrator
- Product code
- JJH
- Device class
- Class I
- Review panel
- Clinical Chemistry
- Regulation
- 21 CFR 862.2310
- Specialty
- Laboratory Medicine & Pathology
- FDA record
- Classification database entry for JJH
Latest FDA decisions
No 510(k), De Novo or PMA decisions for this product code since 2015.
Reports received
15
Received Nov 1, 2025 to Nov 20, 2026
Malfunction reports
5
33% of reports
Injury reports
10
67% of reports
Death reports
0
0.0% of reports
Adverse event reports received per month
By the date FDA received each report, stacked by event type. The newest month is incomplete.
- Malfunction
- Injury
- Death
- Other
View as table
| Month | Malfunction | Injury | Death | Other |
|---|---|---|---|---|
| Dec 23 | 2 | 0 | 0 | 0 |
| Jan 24 | 2 | 0 | 0 | 0 |
| Feb 24 | 1 | 0 | 0 | 0 |
| Mar 24 | 2 | 0 | 0 | 0 |
| Apr 24 | 0 | 0 | 0 | 0 |
| May 24 | 0 | 0 | 0 | 0 |
| Jun 24 | 3 | 1 | 0 | 0 |
| Jul 24 | 0 | 0 | 0 | 0 |
| Aug 24 | 1 | 0 | 0 | 0 |
| Sep 24 | 1 | 0 | 0 | 0 |
| Oct 24 | 1 | 0 | 0 | 0 |
| Nov 24 | 0 | 0 | 0 | 0 |
| Dec 24 | 0 | 0 | 0 | 0 |
| Jan 25 | 4 | 0 | 0 | 0 |
| Feb 25 | 5 | 0 | 0 | 0 |
| Mar 25 | 1 | 0 | 0 | 0 |
| Apr 25 | 0 | 0 | 0 | 0 |
| May 25 | 3 | 0 | 0 | 0 |
| Jun 25 | 1 | 0 | 0 | 0 |
| Jul 25 | 4 | 0 | 0 | 0 |
| Aug 25 | 2 | 1 | 0 | 0 |
| Sep 25 | 1 | 0 | 0 | 0 |
| Oct 25 | 1 | 0 | 0 | 0 |
| Nov 25 | 3 | 0 | 0 | 0 |
| Dec 25 | 1 | 0 | 0 | 0 |
| Jan 26 | 1 | 0 | 0 | 0 |
| Feb 26 | 0 | 0 | 0 | 0 |
| Mar 26 | 0 | 0 | 0 | 0 |
| Apr 26 | 0 | 1 | 0 | 0 |
| May 26 | 0 | 0 | 0 | 0 |
| Jun 26 | 0 | 0 | 0 | 0 |
| Jul 26 | 0 | 8 | 0 | 0 |
| Aug 26 | 0 | 1 | 0 | 0 |
| Sep 26 | 0 | 0 | 0 | 0 |
| Oct 26 | 0 | 0 | 0 | 0 |
| Nov 26 | 0 | 0 | 0 | 0 |
Manufacturers named most often
Last 12 months. Bigger sellers get more reports. This is not a ranking of safety.
1 more in this ranking with a free account
Device problems as coded
Last 12 months. FDA's terms. A report can carry several.
- Low Test Results8
- Low Sensing Threshold2
- Contamination /Decontamination Problem1
6 more in this ranking with a free account
Patient problems as coded
Last 12 months. FDA's terms. A report can carry several.
- No Clinical Signs, Symptoms or Conditions13
- Insufficient Information2
Recent recalls
From FDA's recall database. FDA lists each recalled product separately, so one recall can appear several times. A recall is often a correction or a labeling change, not a removal from the market.
- EMAG system Model/Catalog Number: 418591/418591U Product Description: Nucleic acid sample preparation instrument IVD, automatedOpen, Classified
Z-0301-2027 · Started Sep 11, 2026 · Posted by FDA Oct 27, 2026
Reason given: Delayed or no result when analyzing clinical samples with EMAG system (ref: 418591/418591U) due to a randomly occurring software error, Error 10003 Heater timeout after updating to recent firmware SP4 Patch 2
Cause as FDA categorized it: Software change control
Z-2353-2024 · Started Jun 3, 2024 · Posted by FDA Jul 12, 2024
Reason given: Heater shaker module does not perform heating if the temperature is set below 40C for static incubation steps when running IVD protocol QIAamp DSP DNA Mini Kit (cat. no. 61304), Protocol: Isolation of genomic DNA from Gram-positive bacteria (Script filename: Kt_name_Bacteria (Gram+) or rY'east_Enzymatic Lysis_ V2)...
Cause as FDA categorized it: Software design
Z-1508-2024 · Started Mar 4, 2024 · Posted by FDA Apr 10, 2024
Reason given: Insufficient welding leads to the heater cable becoming brittle and present with an error: ERROR 3481 HEATER UNABLE TO REACH TEMPERATURE; the instrument may stop, and the sample being processed will be lost
Cause as FDA categorized it: Under Investigation by firm
29 more recall records with a free account
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.