With no dates set, the view covers the last 12 full months and the current month. Brand and manufacturer are matched as FDA recorded them, so try the short form of a name. Product code FDS: Gastroscope And Accessories, Flexible/Rigid. Open this device type's page
Reports received
41,649
Received Nov 1, 2025 to Nov 19, 2026. Includes 1 of another or unstated type.
Malfunction reports
41,578
100% of reports
Injury reports
66
0.2% of reports
Death reports
4
0.0% of reports
Reports received per month
product code FDS. By the date FDA received each report, stacked by event type. The newest month is incomplete, and FDA adds reports for recent months as it processes them.
- Malfunction
- Injury
- Death
- Other
View as table
| Month | Malfunction | Injury | Death | Other |
|---|---|---|---|---|
| Nov 25 | 2,812 | 5 | 0 | 0 |
| Dec 25 | 4,112 | 6 | 0 | 0 |
| Jan 26 | 4,138 | 16 | 0 | 0 |
| Feb 26 | 3,211 | 4 | 0 | 0 |
| Mar 26 | 3,197 | 2 | 0 | 0 |
| Apr 26 | 3,530 | 6 | 0 | 0 |
| May 26 | 3,352 | 12 | 0 | 0 |
| Jun 26 | 3,292 | 3 | 0 | 0 |
| Jul 26 | 3,432 | 5 | 0 | 0 |
| Aug 26 | 3,483 | 1 | 1 | 1 |
| Sep 26 | 3,897 | 6 | 0 | 0 |
| Oct 26 | 3,122 | 0 | 3 | 0 |
| Nov 26 | 0 | 0 | 0 | 0 |
Device types with the most reports
By FDA product code. A report that names several devices counts once for each.
Manufacturers with the most reports
Bigger sellers get more reports. This is not a ranking of safety.
- Aizu Olympus40,844
- Fujifilm15
- Olympus15
- Ambu2
Brand names with the most reports
As written on the reports. One product can appear under several spellings.
- PENTAX574
41,649 reports
Showing 1 to 25, newest first. Each title opens FDA's full record, which includes the reporter's description of the event.
- EVIS EXERA III GASTROINTESTINAL VIDEOSCOPEMalfunction
9610595-2026-88184 · Received Oct 30, 2026 · Event dated Oct 13, 2026
Device type: Gastroscope And Accessories, Flexible/Rigid (FDS)
Device problem as coded: No Display/Image
Patient problem as coded: No Clinical Signs, Symptoms or Conditions
- PENTAXMalfunction
9610877-2026-52293 · Received Oct 30, 2026 · Event dated Oct 15, 2026
Device type: Gastroscope And Accessories, Flexible/Rigid (FDS)
Device problem as coded: No Display/Image
Patient problem as coded: No Clinical Signs, Symptoms or Conditions
- PENTAXMalfunction
9610877-2026-52300 · Received Oct 30, 2026 · Event dated Oct 15, 2026
Device type: Gastroscope And Accessories, Flexible/Rigid (FDS)
Device problem as coded: Material Split, Cut or Torn
Patient problem as coded: No Clinical Signs, Symptoms or Conditions
- PENTAXMalfunction
9610877-2026-52305 · Received Oct 30, 2026 · Event dated Oct 15, 2026
Device type: Gastroscope And Accessories, Flexible/Rigid (FDS)
Device problem as coded: Fluid/Blood Leak
Patient problem as coded: No Clinical Signs, Symptoms or Conditions
- PENTAXMalfunction
9610877-2026-52309 · Received Oct 30, 2026 · Event dated Oct 16, 2026
Device type: Gastroscope And Accessories, Flexible/Rigid (FDS)
Device problem as coded: Detachment of Device or Device Component
Patient problem as coded: No Clinical Signs, Symptoms or Conditions
- FUJIFILM Endoscope Model EG-760RMalfunction
3042225166-2026-00006 · Received Oct 30, 2026 · Event dated Sep 28, 2026
Device type: Gastroscope And Accessories, Flexible/Rigid (FDS)
Device problem as coded: Partial Blockage
Patient problem as coded: No Clinical Signs, Symptoms or Conditions
9610595-2026-88247 · Received Oct 30, 2026 · Event dated Oct 2, 2026
Device type: Gastroscope And Accessories, Flexible/Rigid (FDS)
Device problem as coded: Material Too Rigid or Stiff
Patient problem as coded: No Clinical Signs, Symptoms or Conditions
9610595-2026-88248 · Received Oct 30, 2026 · Event dated Aug 20, 2026
Device type: Gastroscope And Accessories, Flexible/Rigid (FDS)
Device problem as coded: Misfocusing
Patient problem as coded: No Clinical Signs, Symptoms or Conditions
9610595-2026-88249 · Received Oct 30, 2026 · Event dated Oct 1, 2026
Device type: Gastroscope And Accessories, Flexible/Rigid (FDS)
Device problem as coded: Communication or Transmission Problem
Patient problem as coded: No Clinical Signs, Symptoms or Conditions
- GASTROINTESTINAL VIDEOSCOPEMalfunction
9610595-2026-88255 · Received Oct 30, 2026 · Event dated Oct 1, 2026
Device type: Gastroscope And Accessories, Flexible/Rigid (FDS)
Device problem as coded: Material Too Rigid or Stiff
Patient problem as coded: No Clinical Signs, Symptoms or Conditions
- GASTROINTESTINAL VIDEOSCOPEMalfunction
9610595-2026-88256 · Received Oct 30, 2026 · Event dated Oct 5, 2026
Device type: Gastroscope And Accessories, Flexible/Rigid (FDS)
Device problem as coded: Device Reprocessing Problem
Patient problem as coded: No Clinical Signs, Symptoms or Conditions
- GASTROINTESTINAL VIDEOSCOPEMalfunction
9610595-2026-88257 · Received Oct 30, 2026 · Event dated Oct 5, 2026
Device type: Gastroscope And Accessories, Flexible/Rigid (FDS)
Device problem as coded: No Display/Image
Patient problem as coded: No Clinical Signs, Symptoms or Conditions
- GASTROINTESTINAL VIDEOSCOPEMalfunction
9610595-2026-88259 · Received Oct 30, 2026 · Event dated Sep 25, 2026
Device type: Gastroscope And Accessories, Flexible/Rigid (FDS)
Device problem as coded: No Display/Image; Communication or Transmission Problem
Patient problem as coded: No Clinical Signs, Symptoms or Conditions
- GASTROINTESTINAL VIDEOSCOPEMalfunction
9610595-2026-88261 · Received Oct 30, 2026 · Event dated Oct 8, 2026
Device type: Gastroscope And Accessories, Flexible/Rigid (FDS)
Device problem as coded: Corroded; No Display/Image
Patient problem as coded: No Clinical Signs, Symptoms or Conditions
- GASTROINTESTINAL VIDEOSCOPEMalfunction
9610595-2026-88263 · Received Oct 30, 2026
Device type: Gastroscope And Accessories, Flexible/Rigid (FDS)
Device problem as coded: Erratic or Intermittent Display; Communication or Transmission Problem; Connection Problem
Patient problem as coded: No Clinical Signs, Symptoms or Conditions
- GASTROINTESTINAL VIDEOSCOPEMalfunction
9610595-2026-88265 · Received Oct 30, 2026 · Event dated Oct 9, 2026
Device type: Gastroscope And Accessories, Flexible/Rigid (FDS)
Device problem as coded: Residue After Decontamination
Patient problem as coded: No Clinical Signs, Symptoms or Conditions
9610595-2026-88271 · Received Oct 30, 2026 · Event dated Sep 29, 2026
Device type: Gastroscope And Accessories, Flexible/Rigid (FDS)
Device problem as coded: Failure to Clean Adequately
Patient problem as coded: No Clinical Signs, Symptoms or Conditions
9610595-2026-88277 · Received Oct 30, 2026 · Event dated Sep 1, 2026
Device type: Gastroscope And Accessories, Flexible/Rigid (FDS)
Device problem as coded: Failure to Clean Adequately
Patient problem as coded: No Clinical Signs, Symptoms or Conditions
- EVIS EXERA III GASTROINTESTINAL VIDEOSCOPEMalfunction
9610595-2026-88280 · Received Oct 30, 2026 · Event dated Oct 6, 2026
Device type: Gastroscope And Accessories, Flexible/Rigid (FDS)
Device problem as coded: Contamination; Residue After Decontamination; Optical Problem
Patient problem as coded: No Clinical Signs, Symptoms or Conditions
9610595-2026-88284 · Received Oct 30, 2026 · Event dated Sep 29, 2026
Device type: Gastroscope And Accessories, Flexible/Rigid (FDS)
Device problem as coded: Failure to Clean Adequately
Patient problem as coded: No Clinical Signs, Symptoms or Conditions
- EVIS EXERA lll GASTROINTESTINAL VIDEOSCOPEMalfunction
9610595-2026-88292 · Received Oct 30, 2026 · Event dated Sep 30, 2026
Device type: Gastroscope And Accessories, Flexible/Rigid (FDS)
Device problem as coded: Device Reprocessing Problem; Erratic or Intermittent Display; No Display/Image
Patient problem as coded: No Clinical Signs, Symptoms or Conditions
- GASTROINTESTINAL VIDEOSCOPEMalfunction
9610595-2026-88293 · Received Oct 30, 2026 · Event dated Sep 29, 2026
Device type: Gastroscope And Accessories, Flexible/Rigid (FDS)
Device problem as coded: Device Reprocessing Problem
Patient problem as coded: No Clinical Signs, Symptoms or Conditions
- EVIS EXERA III GASTROINTESTINAL VIDEOSCOPEMalfunction
9610595-2026-88415 · Received Oct 30, 2026
Device type: Gastroscope And Accessories, Flexible/Rigid (FDS)
Device problem as coded: Device Reprocessing Problem; Flare or Flash
Patient problem as coded: No Clinical Signs, Symptoms or Conditions
- GASTROINTESTINAL VIDEOSCOPEMalfunction
9610595-2026-88417 · Received Oct 30, 2026
Device type: Gastroscope And Accessories, Flexible/Rigid (FDS)
Device problem as coded: No Display/Image; Communication or Transmission Problem
Patient problem as coded: No Clinical Signs, Symptoms or Conditions
9610595-2026-87855 · Received Oct 29, 2026
Device type: Gastroscope And Accessories, Flexible/Rigid (FDS)
Device problem as coded: Flare or Flash
Patient problem as coded: No Clinical Signs, Symptoms or Conditions
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.