HiResolution™ Bionic Ear System

A PMA supplement is a change to a device that already has premarket approval, such as a new indication, a design change or a manufacturing change.

Last checked: Nov 20, 2026Latest source record: Jul 22, 2026 (this decision)Source: openFDAMethods & limitations

PMA supplement

Decided

Jul 22, 2026

Approved

Time to decision

539 days

Received Jan 29, 2025. Calendar days, including time FDA spent waiting on the applicant.

Pathway

PMA supplement

Panel Track

Device class

Class III

The decision

FDA number
P960058-S167
Device name
HiResolution™ Bionic Ear System
Applicant location
Valencia, CA
Received
Jan 29, 2025
Decided
Jul 22, 2026
Decision
Approved
Supplement type
Panel Track
Reason for supplement
Labeling Change - Indications/instructions/shelf life/tradename
Original approval
P960058

Device type

Device class
Class III

Every decision under product code MCM

FDA's approval statement

As written in FDA's record.

Unilateral Hearing Loss The HiResolution™ Bionic Ear System is indicated for individuals with unilateral hearing loss who meet the following criteria: Asymmetric Hearing Loss (AHL) Individuals with AHL are defined as those with a mild to moderately severe hearing loss in the better ear, i.e., a 4PTA of 31 to 65 dB HL at 500 Hz, 1000 Hz, 2000 Hz and 4000 Hz, with a difference of at least 15 dB in the 4PTA between ears. It is recommended that individuals with AHL have at least two (2) weeks experience wearing an appropriately fitted Contralateral Routing of Signal (CROS) system or suitable hearing device prior to cochlear implantation. The ear to be implanted will be as follows: Adults (18 years of age or older): Severe to profound sensorineural hearing loss (4PTA of 500, 1000, 2000, and 4000 Hz = 80 dB HL) A score of = 20% on a Consonant-Nucleus-Consonant (CNC) word test Children (5 years through 17 years of age): Profound sensorineural hearing loss (4PTA of 500, 1000, 2000, and 4000 Hz = 90 dB HL) Insufficient functional access to sound in the ear to be implanted must be determined by aided speech perception test scores of 5% or less on a developmentally appropriate monosyllabic word list when tested in the ear to be implanted alone. Single-Sided Deafness (SSD) Individuals with SSD are defined as those with normal hearing or mild sensorineural hearing loss in the better ear (4PTA of = 30 dB HL at 500, 1000, 2000, and 4000 Hz). It is recommended that individuals with SSD have at least two (2) weeks experience wearing an appropriately fitted Contralateral Routing of Signal (CROS) system or suitable hearing device prior to cochlear implantation. The ear to be implanted will be as follows: Adults (18 years of age or older): Severe to profound sensorineural hearing loss (4PTA of 500, 1000, 2000, and 4000 Hz = 80 dB HL) A score of = 20% on a Consonant-Nucleus-Consonant (CNC) word test Children (5 years through 17 years of age): Profound sensorineural hearing loss (4PTA of 500, 1000, 2000, and 4000 Hz = 90 dB HL) Insufficient functional access to sound in the ear to be implanted must be determined by aided speech perception test scores of 5% or less on a developmentally appropriate monosyllabic word list when tested in the ear to be implanted alone.

Source documents

Other decisions for Advanced Bionics

Matched on the applicant name as FDA recorded it. A company that files under several names will have more.

Company page

No other decisions since 2015 under this exact applicant name.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.