All In MedTech

FDA Clearance Tracker · P020018-S064

Zenith® Iliac Branch

A PMA supplement is a change to a device that already has premarket approval, such as a new indication, a design change or a manufacturing change.

Last checked: Nov 20, 2026Latest source record: May 30, 2025 (this decision)Source: openFDAMethods & limitations

PMA supplement

Decided

May 30, 2025

Approved

Time to decision

302 days

Received Aug 1, 2024. Calendar days, including time FDA spent waiting on the applicant.

Pathway

PMA supplement

Panel Track

Device class

Class III

The decision

FDA number
P020018-S064
Device name
Zenith® Iliac Branch
Applicant
Cook, Inc.
Applicant location
Bloomington, IN
Received
Aug 1, 2024
Decided
May 30, 2025
Decision
Approved
Supplement type
Panel Track
Reason for supplement
Change Design/Components/Specifications/Material
Original approval
P020018

Device type

Device class
Class III

Every decision under product code MIH

FDA's approval statement

As written in FDA's record.

Approval for the Zenith Iliac Branch. The Zenith Iliac Branch, when used with the necessary additional components (Zenith AAA devices and a covered bridging stent), is indicated for endovascular treatment of aortoiliac or iliac aneurysms to preserve internal iliac arterial blood flow when the distal sealing site in the common iliac artery is insufficient for the AAA device alone and when the vessel morphology is suitable for repair: 1) Common iliac artery diameter at the level of the internal iliac artery (luminal diameter) ?16 mm; 2) Adequate iliac/femoral access compatible with a 20 French (7.7mm O.D.) introduction system; 3) Non-aneurysmal external iliac artery fixation segment distal to the aneurysm: with a length of at least 20mm and with a diameter measured outer wall to outer wall of no greater than 11mm and no less than 8mm; 4) Non-aneurysmal internal iliac artery segment distal to the aneurysm: with a length of at least 10mm (with 20-30mm being preferred) and with a diameter measured outer wall to outer wall no greater than 10mm and no less than 7mm

Source documents

Other decisions for Cook, Inc.

Matched on the applicant name as FDA recorded it. A company that files under several names will have more.

Company page

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.