PMA device
Model 3100B High Frequency Oscillatory Ventilator (Hfov)
ZOLL Medical Corporation · Ventilator, High Frequency (LSZ, Class III) · First FDA decision Sep 24, 2001, newest Sep 24, 2001Respiratory failure and ventilation
Last checked: Nov 20, 2026Source: FDA, CMS, ClinicalTrials.gov, PubMed
FDA decisions
1
PMA pathway
Device trials
1
Naming "3100B"
MAUDE reports
28
Brand "3100B", since 2015
PubMed studies
12
Mentioning "3100B"
AI summary across all sources
Written by AI from the FDA, CMS, ClinicalTrials.gov, MAUDE and PubMed data on this page, plus web searches for payment facts.
Product review deck
A slide deck reviewing Model 3100B High Frequency Oscillatory Ventilator (Hfov)
About ten slides on the technology, clinical evidence, regulatory history and commercialization, built with AI from the data on this page and web research, with sources. Download it as PowerPoint to edit or as PDF to share.
- Executive summary and key facts
- Technology
- Clinical evidence and trials
- Regulatory history and safety
- Reimbursement, market and competition
- Risks, outlook and sources
AI-written from public data and may contain mistakes. Check each fact against its source before relying on it. Not investment, legal, reimbursement or medical advice.
FDA decisions
The newest 1 of 1 decisions filed under this name.
- MODEL 3100B HIGH FREQUENCY OSCILLATORY VENTILATOR (HFOV)PMA supplement
P890057-S014 · Decided Sep 24, 2001 · 214 days after receipt · Panel Track
Device type: VENTILATOR, HIGH FREQUENCY (LSZ) · Anesthesiology & Respiratory
Medicare coverage
National and local coverage documents whose titles match this device or its device type. Payment add-ons (NTAP, pass-through, TCET) and likely codes are covered in the summary above.
No Medicare coverage document has a title matching this device or device type. Many devices are paid under existing codes without one.
Clinical trials
Device studies on ClinicalTrials.gov that name "3100B", any status and sponsor, newest update first.
- The Oscillation for Acute Respiratory Distress Syndrome (ARDS) Treated Early (OSCILLATE) TrialPivotal-lookingTerminated
Canadian Critical Care Trials GroupAcademic, hospital or other
NCT01506401 · 548 participants · Start Jun 2009 · Primary completion Sep 2012
Device: SensorMedics 3100B High Frequency Oscillatory Ventilator · For: Acute Respiratory Distress Syndrome (ARDS)
Sites: Denver, Colorado; Orlando, Florida; Ann Arbor, Michigan · 38 sites in all
Adverse event reports (MAUDE)
Reports received since 2015 naming the brand "3100B", and for the whole product code for context.
This brand
28 reports: 19 malfunction, 9 injury, 0 death
Whole product code LSZ
1,938 reports: 1,420 malfunction, 500 injury, 16 death
Newest reports for this brand
- 3100B HFOVMalfunction
3013421741-2026-00226 · Received Jun 11, 2026 · Event dated May 13, 2026
Device type: Ventilator, High Frequency (LSZ)
Device problem as coded: Unexpected Shutdown
Patient problem as coded: No Clinical Signs, Symptoms or Conditions
- 3100B HFOVMalfunction
3013421741-2026-00243 · Received Jun 5, 2026 · Event dated May 15, 2026
Device type: Ventilator, High Frequency (LSZ)
Device problem as coded: False Alarm
Patient problem as coded: No Clinical Signs, Symptoms or Conditions
- 3100B HFOVMalfunction
3013421741-2026-00170 · Received Apr 21, 2026 · Event dated Mar 24, 2026
Device type: Ventilator, High Frequency (LSZ)
Device problem as coded: Failure to Power Up
Patient problem as coded: No Clinical Signs, Symptoms or Conditions
2 more reports with a free account
Recalls
From FDA's recall database. FDA lists each recalled product separately, so one recall can appear several times. A recall is often a correction or a labeling change, not a removal from the market.
Z-0488-2024 · Started Oct 27, 2023 · Posted by FDA Dec 5, 2023
Reason given: Two patient circuits, 29028-003 and 29028-004, for the 3100 High Frequency Oscillatory ventilator that are only approved for use outside the U.S. were distributed in the U.S.
Cause as FDA categorized it: Process control · Device type: Ventilator, High Frequency (LSZ)
Published research
The most relevant PubMed records for "3100B"[tiab]. The summary above synthesizes these.
- In vitro performance comparison of the Sensormedics 3100A and B high-frequency oscillatory ventilators.
Custer JW, Ahmed A, Kaczka DW, et al. · Pediatr Crit Care Med · 2011Comparative Study, Evaluation Study
- Mean lung pressure during adult high-frequency oscillatory ventilation: an experimental study using a lung model.
Hirayama T, Nagano O, Shiba N, et al. · Acta Med Okayama · 2014Comparative Study
- Comparison of the ventilation characteristics in two adult oscillators: a lung model study.
Yumoto T, Fujita T, Asaba S, et al. · Intensive Care Med Exp · 2019
- Humidification during high-frequency oscillatory ventilation for adults: a bench study.
Chikata Y, Imanaka H, Ueta M, et al. · Med Sci Monit · 2010Comparative Study, Evaluation Study
- Tidal volume delivery during high-frequency oscillatory ventilation in adults with acute respiratory distress syndrome.
Hager DN, Fessler HE, Kaczka DW, et al. · Crit Care Med · 2007Research Support, N.I.H., Extramural, Research Support, Non-U.S. Gov't
- Determinants of tidal volume during high-frequency oscillation.
Sedeek KA, Takeuchi M, Suchodolski K, et al. · Crit Care Med · 2003Evaluation Study, Research Support, Non-U.S. Gov't
- Unloading work of breathing during high-frequency oscillatory ventilation: a bench study.
van Heerde M, Roubik K, Kopelent V, et al. · Crit Care · 2006Research Support, Non-U.S. Gov't
- Four methods of measuring tidal volume during high-frequency oscillatory ventilation.
Hager DN, Fuld M, Kaczka DW, et al. · Crit Care Med · 2006Evaluation Study, Research Support, N.I.H., Extramural
- High-frequency oscillation in adolescents.
Moganasundram S, Durward A, Tibby SM, et al. · Br J Anaesth · 2002
- Evaluation of performance of two high-frequency oscillatory ventilators using a model lung with a position sensor.
Iguchi N, Hirao O, Uchiyama A, et al. · J Anesth · 2010Evaluation Study
- CareFusion 3100B high-frequency oscillatory ventilator diaphragms require pre-use inspection.
Health Devices · 2011
- CareFusion 3100A and 3100B high-frequency oscillatory ventilator breathing circuit component may be defective and not hold pressure.
Health Devices · 2012
Other devices of this type
Also filed under product code LSZ.
- Life Pulse High Frequency VentilatorBunnell, Inc. · PMA 2016
- LifePulse® High Frequency VentilatorBunnell, Inc. · PMA 2026
- Model 3100B High Frequency Oscillatory VentilatorZOLL Medical Corporation · PMA 2005
- Nellcor Puritan Bennett Infant Star High Frequency VentilatorNellcor Puritan Bennett, Inc. · PMA 2002
- High Frequency Oscillatory VentilatorZOLL Medical Corporation · PMA 2002
- Electromechanical Enhancement to DriverZOLL Medical Corporation · PMA 2000
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.