PMA device
Medtronic CareLink Monitor, CardioSight Reader
Medtronic, Inc. · Pulse Generator, Permanent, Implantable (NVZ, Class III) · First FDA decision Nov 9, 2007, newest Mar 5, 2019Bradycardia and heart blockHeart failure
Last checked: Nov 19, 2026Source: FDA, CMS, ClinicalTrials.gov, PubMed
FDA decisions
5
PMA pathway
Device trials
6
Naming "Medtronic CareLink"
MAUDE reports
198
Brand "Medtronic CareLink", since 2015
PubMed studies
58
Mentioning "Medtronic CareLink"
AI summary across all sources
Written by AI from the FDA, CMS, ClinicalTrials.gov, MAUDE and PubMed data on this page, plus web searches for payment facts.
Product review deck
A slide deck reviewing Medtronic CareLink Monitor, CardioSight Reader
About ten slides on the technology, clinical evidence, regulatory history and commercialization, built with AI from the data on this page and web research, with sources. Download it as PowerPoint to edit or as PDF to share.
- Executive summary and key facts
- Technology
- Clinical evidence and trials
- Regulatory history and safety
- Reimbursement, market and competition
- Risks, outlook and sources
AI-written from public data and may contain mistakes. Check each fact against its source before relying on it. Not investment, legal, reimbursement or medical advice.
FDA decisions
The newest 5 of 5 decisions filed under this name.
- Medtronic CareLink Monitor, CardioSight ReaderPMA supplement
P890003-S403 · Decided Mar 5, 2019 · 34 days after receipt · Normal 180 Day Track No User Fee
Device type: Pulse generator, permanent, implantable (NVZ) · Cardiology
P890003-S259 · Decided Apr 3, 2013 · 211 days after receipt · Normal 180 Day Track
Device type: Pulse generator, permanent, implantable (NVZ) · Cardiology
- MEDTRONIC CARELINK MONITOR, CARDIOSIGHT READERPMA supplement
P890003-S214 · Decided May 2, 2012 · 448 days after receipt · Normal 180 Day Track
Device type: Pulse generator, permanent, implantable (NVZ) · Cardiology
2 more FDA decisions with a free account
Medicare coverage
National and local coverage documents whose titles match this device or its device type. Payment add-ons (NTAP, pass-through, TCET) and likely codes are covered in the summary above.
No Medicare coverage document has a title matching this device or device type. Many devices are paid under existing codes without one.
Clinical trials
Device studies on ClinicalTrials.gov that name "Medtronic CareLink", any status and sponsor, newest update first.
- OptiLink HF Study: Optimization of Heart Failure Management Using Medtronic OptiVol Fluid Status Monitoring and CareLink NetworkPivotal-lookingCompleted
Medtronic Cardiac Rhythm and Heart FailurePublic (MDT)
NCT00769457 · 1,002 participants · Start Sep 2008 · Primary completion Nov 2014
Device: Access Arm · For: Heart Failure
Sites: Homburg-Saar, Germany
- MOnitoring REsynchronization deviCes and cARdiac patiEntsPivotal-lookingTerminated
Medtronic Cardiac Rhythm and Heart FailurePublic (MDT)
NCT00885677 · 918 participants · Start Jun 2009 · Primary completion Dec 2015
Device: Medtronic CareLink® Network · For: Heart Failure
Sites: Prague, Czechia; Angers, France; Bordeaux, France · 64 sites in all
NYU Langone HealthAcademic, hospital or other
NCT03519347 · 19 participants · Start Nov 30, 2018 · Primary completion Jul 12, 2022
Device: Cardiac Monitor · For: End Stage Renal Disease
Sites: Durham, North Carolina
3 more trials with a free account
Adverse event reports (MAUDE)
Reports received since 2015 naming the brand "Medtronic CareLink", and for the whole product code for context.
This brand
198 reports: 197 malfunction, 1 injury, 0 death
Whole product code NVZ
72,953 reports: 32,608 malfunction, 38,411 injury, 1,913 death
Newest reports for this brand
- Medtronic CareLink Programmer with AnalyzerMalfunction
2182208-2026-58330 · Received Oct 12, 2026 · Event dated Oct 5, 2026
Device type: Programmer, Pacemaker (KRG)
Device problem as coded: No Display/Image; Display or Visual Feedback Problem
Patient problem as coded: No Clinical Signs, Symptoms or Conditions
- Medtronic CareLink Programmer with AnalyzerMalfunction
2182207-2026-02442 · Received Sep 2, 2026 · Event dated Aug 27, 2026
Device type: Programmer, Pacemaker (KRG)
Device problem as coded: No Display/Image; Display or Visual Feedback Problem
Patient problem as coded: No Clinical Signs, Symptoms or Conditions
- MEDTRONIC CARELINK PROGRAMMER WITH ANALYZERMalfunction
2182208-2026-41569 · Received Jul 8, 2026 · Event dated Jun 26, 2026
Device type: Programmer, Pacemaker (KRG)
Device problem as coded: No Display/Image
Patient problem as coded: No Clinical Signs, Symptoms or Conditions
2 more reports with a free account
Recalls
From FDA's recall database. FDA lists each recalled product separately, so one recall can appear several times. A recall is often a correction or a labeling change, not a removal from the market.
- CareLink SmartSync Programmer, Model 24970A, Pulse generator, permanent, implantableOpen, Classified
Z-0302-2027 · Started Sep 24, 2026 · Posted by FDA Oct 27, 2026
Reason given: Software problem has the potential for an inaccurate displayed longevity estimate.
Cause as FDA categorized it: Software design · Device type: Pulse Generator, Permanent, Implantable (NVZ)
- CareLink SmartSync, RF Head Patient Connector, Model 24967, Pulse generator, permanent, implantableOpen, Classified
Z-0303-2027 · Started Sep 24, 2026 · Posted by FDA Oct 27, 2026
Reason given: Software problem has the potential for an inaccurate displayed longevity estimate.
Cause as FDA categorized it: Software design · Device type: Pulse Generator, Permanent, Implantable (NVZ)
- CareLink SmartSync Device Manager App, Model M01A02, Pulse generator, permanent, implantableOpen, Classified
Z-0304-2027 · Started Sep 24, 2026 · Posted by FDA Oct 27, 2026
Reason given: Software problem has the potential for an inaccurate displayed longevity estimate.
Cause as FDA categorized it: Software design · Device type: Pulse Generator, Permanent, Implantable (NVZ)
10 more recall records with a free account
Published research
The most relevant PubMed records for "Medtronic CareLink"[tiab]. The summary above synthesizes these.
- Effectiveness of Medtronic CareLink Express System in identifying patients with high-energy electrotherapy devices requiring clinically significant intervention.
Grabowski M, Sadecka S, Cacko A, et al. · Cardiol J · 2018
- Contemporary Implantable Cardioverter-Defibrillator Benefit: Time to First Therapy in a Large, Real-World Cohort.
Curtis AB, Auricchio A, Mittal S, et al. · JACC Clin Electrophysiol · 2025Research Support, Non-U.S. Gov't
- Performance of alert transmissions from cardiac implantable electronic devices to the CareLink network: A retrospective analysis.
Cronin EM, Green JC, Lande J, et al. · Cardiovasc Digit Health J · 2023
- Reactive atrial-based antitachycardia pacing therapy reduces atrial tachyarrhythmias.
Crossley GH, Padeletti L, Zweibel S, et al. · Pacing Clin Electrophysiol · 2019Multicenter Study
- Feasibility of His bundle pacing facilitated by EASI derived 12ߛlead ECG.
Langanke A, Andreas K · J Electrocardiol · 2023
- Performance of Atrial Fibrillation Burden Trends for Stroke Risk Stratification.
Piccini JP, Stanelle EJ, Johnson CC, et al. · Circ Arrhythm Electrophysiol · 2024
- When Legacy Triumphs: Resolving Leadless Pacemaker Programming Failure Caused by Loop Recorder Interference.
Pavani G, Previti A, Garrone P, et al. · Pacing Clin Electrophysiol · 2025Case Reports
- Impact of Atrial Fibrillation Burden on Health Care Costs and Utilization.
Peigh G, Zhou J, Rosemas SC, et al. · JACC Clin Electrophysiol · 2024
- Remote monitoring of cardiac implantable electronic devices to predict acute clinical decompensation events.
Tinoco M, Castro M, Mota M, et al. · Pacing Clin Electrophysiol · 2024
- Impact of atrial fibrillation ablation on activity minutes in patients with cardiac implantable electronic devices.
Peigh G, Stanelle E, Ziegler PD, et al. · Heart Rhythm · 2022
- Association of Atrial Fibrillation Burden and Mortality Among Patients With Cardiac Implantable Electronic Devices.
Peigh G, Zhou J, Rosemas SC, et al. · Circulation · 2024
- Frequency of CIED remote monitoring: A quality improvement follow-up study.
Dechert BE, Bradley DJ, Serwer GA, et al. · Pacing Clin Electrophysiol · 2019
Other devices of this type
Also filed under product code NVZ.
- CareLink Instruments & DDMA, CareLink SmartSync Common ApplicationMedtronic, Inc. · PMA 2023
- Affinity/Integrity/Victory/Zephyr/Accent Family of PacemakersAbbott Medical · PMA 2016
- Adapta, Versa, Sensia IPGEnPulse E1 IPG Kappa DR (Kappa 700/600)Medtronic, Inc. · PMA 2017
- Various Families of PacemakersMedtronic, Inc. · PMA 2008
- Cadence Family of IcdsAbbott Medical · PMA 2012
- Legend Plus Family of PacemakersMedtronic, Inc. · PMA 2011
- Advisa DR MRI SureScan Model A2DR01 IPG, Advisa SR MRI SureScan Model A3SR01 IPGMedtronic, Inc. · PMA 2022
- AdaptaMedtronic, Inc. · PMA 2020
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.