PMA device
LINX Reflux Management System
Torax Medical · Implant, Anti-Gastroesophageal Reflux (LEI, Class III) · First FDA decision Mar 22, 2012, newest Oct 8, 2025Acid reflux (GERD)
Last checked: Nov 20, 2026Source: FDA, CMS, ClinicalTrials.gov, PubMed
FDA decisions
12
PMA pathway
Device trials
11
Naming "LINX"
MAUDE reports
2,110
Brand "LINX", since 2015
PubMed studies
205
Mentioning "LINX"
AI summary across all sources
Written by AI from the FDA, CMS, ClinicalTrials.gov, MAUDE and PubMed data on this page, plus web searches for payment facts.
Product review deck
A slide deck reviewing LINX Reflux Management System
About ten slides on the technology, clinical evidence, regulatory history and commercialization, built with AI from the data on this page and web research, with sources. Download it as PowerPoint to edit or as PDF to share.
- Executive summary and key facts
- Technology
- Clinical evidence and trials
- Regulatory history and safety
- Reimbursement, market and competition
- Risks, outlook and sources
AI-written from public data and may contain mistakes. Check each fact against its source before relying on it. Not investment, legal, reimbursement or medical advice.
FDA decisions
The newest 6 of 12 decisions filed under this name.
- LINX Reflux Management SystemPMA supplement
P100049-S038 · Decided Oct 8, 2025 · 292 days after receipt · Normal 180 Day Track No User Fee
Device type: IMPLANT, ANTI-GASTROESOPHAGEAL REFLUX (LEI) · GI, Urology & Nephrology
- LINX Reflux Management SystemPMA supplement
P100049-S037 · Decided Feb 22, 2024 · 87 days after receipt · Normal 180 Day Track
Device type: IMPLANT, ANTI-GASTROESOPHAGEAL REFLUX (LEI) · GI, Urology & Nephrology
- LINX Reflux Management SystemPMA supplement
P100049-S033 · Decided Oct 4, 2022 · 179 days after receipt · Normal 180 Day Track
Device type: IMPLANT, ANTI-GASTROESOPHAGEAL REFLUX (LEI) · GI, Urology & Nephrology
3 more FDA decisions with a free account
Older decisions: P100049-S011, P100049-S004, P100049-S003, P100049-S002, P100049-S001, P100049
Medicare coverage
National and local coverage documents whose titles match this device or its device type. Payment add-ons (NTAP, pass-through, TCET) and likely codes are covered in the summary above.
No Medicare coverage document has a title matching this device or device type. Many devices are paid under existing codes without one.
Clinical trials
Device studies on ClinicalTrials.gov that name "LINX", any status and sponsor, newest update first.
- RETHINK REFLUX RegistryActive, not recruiting
Ethicon Endo-SurgeryPublic (JNJ)
NCT04253392 · 500 participants · Start Jul 8, 2020 · Primary completion Jul 31, 2032
Device: LINX Reflux Management System · For: Gastroesophageal Reflux
Sites: Mobile, Alabama; Tucson, Arizona; Los Angeles, California · 28 sites in all
- PMCF Study of GX-01S CGM in Adults With DiabetesNot yet recruiting
MicroTech Medical(Hangzhou)Co.,Ltd.Not on our public-company list
NCT07802327 · 100 participants (planned) · Start Sep 2026 · Primary completion Feb 2028
Device: GX-01S Continuous Glucose Monitoring System · For: Diabetes Mellitus; Diabetes Mellitus ( Type 1 and Type 2)
- SnapDandCGMinType2DMRecruiting
Ramathibodi HospitalAcademic, hospital or other
NCT07533604 · 45 participants (planned) · Start Jan 20, 2026 · Primary completion Sep 1, 2026
Device: SnapD; Linx CGM · For: Type2 Diabetes Mellitus
Sites: Bangkok, Thailand
8 more trials with a free account
Adverse event reports (MAUDE)
Reports received since 2015 naming the brand "LINX", and for the whole product code for context.
This brand
2,110 reports: 95 malfunction, 2,013 injury, 1 death
Whole product code LEI
2,179 reports: 98 malfunction, 2,079 injury, 1 death
Newest reports for this brand
- LINXInjury
3008766073-2026-00128 · Received Oct 29, 2026 · Event dated Jan 1, 2026
Device type: Implant, Anti-Gastroesophageal Reflux (LEI)
Device problem as coded: Detachment of Device or Device Component
Patient problem as coded: Insufficient Information
- LINXInjury
3008766073-2026-00127 · Received Oct 27, 2026 · Event dated Oct 13, 2026
Device type: Implant, Anti-Gastroesophageal Reflux (LEI)
Device problem as coded: Device Appears to Trigger Rejection; Adverse Event Without Identified Device or Use Problem; Patient Device Interaction Problem
Patient problem as coded: Dysphagia/ Odynophagia; Hernia; Abdominal Distention
- LINXInjury
3008766073-2026-00124 · Received Oct 22, 2026 · Event dated May 30, 2018
Device type: Implant, Anti-Gastroesophageal Reflux (LEI)
Device problem as coded: Migration or Expulsion of Device
Patient problem as coded: Insufficient Information
2 more reports with a free account
Recalls
From FDA's recall database. FDA lists each recalled product separately, so one recall can appear several times. A recall is often a correction or a labeling change, not a removal from the market.
Z-2037-2018 · Started Apr 20, 2018
Reason given: Possible out of specification condition which may allow a bead component to separate from an adjacent wire link. This condition may result in a discontinuous or open LINX device.
Cause as FDA categorized it: Nonconforming Material/Component · Device type: Implant, Anti-Gastroesophageal Reflux (LEI)
Z-2038-2018 · Started Apr 20, 2018
Reason given: Possible out of specification condition which may allow a bead component to separate from an adjacent wire link. This condition may result in a discontinuous or open LINX device.
Cause as FDA categorized it: Nonconforming Material/Component · Device type: Implant, Anti-Gastroesophageal Reflux (LEI)
Z-2039-2018 · Started Apr 20, 2018
Reason given: Possible out of specification condition which may allow a bead component to separate from an adjacent wire link. This condition may result in a discontinuous or open LINX device.
Cause as FDA categorized it: Nonconforming Material/Component · Device type: Implant, Anti-Gastroesophageal Reflux (LEI)
2 more recall records with a free account
Published research
The most relevant PubMed records for "LINX"[tiab]. The summary above synthesizes these.
- LinX: A Software Tool for Uncommon Cross-Linking Chemistry.
Kukačka Z, Rosůlek M, Jelínek J, et al. · J Proteome Res · 2021Research Support, Non-U.S. Gov't
- Essential Role of Linx/Islr2 in the Development of the Forebrain Anterior Commissure.
Abudureyimu S, Asai N, Enomoto A, et al. · Sci Rep · 2018Research Support, Non-U.S. Gov't
- Linx mediates interaxonal interactions and formation of the internal capsule.
Mandai K, Reimert DV, Ginty DD · Neuron · 2014Research Support, N.I.H., Extramural, Research Support, Non-U.S. Gov't
- High-resolution manometry findings after Linx procedure for gastro-esophageal reflux disease.
Riva CG, Siboni S, Sozzi M, et al. · Neurogastroenterol Motil · 2020Observational Study, Research Support, Non-U.S. Gov't
- Laparoscopic placement of the LINX® system in management of severe reflux after sleeve gastrectomy.
Hawasli A, Sadoun M, Meguid A, et al. · Am J Surg · 2019
- Robotic LINX Placement: Is it Worth It?
Wahi JE, Le C, Yousef M, et al. · J Laparoendosc Adv Surg Tech A · 2021Comparative Study
- The Use of LINX for Gastroesophageal Reflux.
Zak Y, Rattner DW · Adv Surg · 2016Review
- Robotic Magnetic Sphincter Augmentation Device Removal.
Emengo P, Nicastri D, Jacob J · Innovations (Phila) · 2024
- Evaluation of post-operative dysphagia following anti-reflux surgery.
Greenberg JA, Stefanova DI, Reyes FV, et al. · Surg Endosc · 2022Research Support, N.I.H., Extramural, Research Support, Non-U.S. Gov't
- Magnetic challenge against gastroesophageal reflux.
Bortolotti M · World J Gastroenterol · 2021Review
- Evaluation of the LINX antireflux procedure.
Sheu EG, Rattner DW · Curr Opin Gastroenterol · 2015Review
- Augmentation of the Esophageal Sphincter Using LINX.
Bridges LC, Shillinglaw JP, Smith BE, et al. · Am Surg · 2022
Other devices of this type
Also filed under product code LEI.
- RefluxStop® Device and RefluxStop® Deployment ToolImplantica CE Reflux , Ltd. · PMA 2026
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.