PMA device
Thoratec Heartmate II Left Ventricular Assist System
Abbott Medical · Ventricular (Assist) Bypass (DSQ, Class III) · First FDA decision Apr 21, 2008, newest Jun 23, 2017Heart failure
Last checked: Nov 19, 2026Source: FDA, CMS, ClinicalTrials.gov, PubMed
FDA decisions
7
PMA pathway
Device trials
6
Naming "Thoratec Heartmate II"
MAUDE reports
21
Brand "Thoratec Heartmate II", since 2015
PubMed studies
36
Mentioning "Thoratec Heartmate II"
AI summary across all sources
Written by AI from the FDA, CMS, ClinicalTrials.gov, MAUDE and PubMed data on this page, plus web searches for payment facts.
Product review deck
A slide deck reviewing Thoratec Heartmate II Left Ventricular Assist System
About ten slides on the technology, clinical evidence, regulatory history and commercialization, built with AI from the data on this page and web research, with sources. Download it as PowerPoint to edit or as PDF to share.
- Executive summary and key facts
- Technology
- Clinical evidence and trials
- Regulatory history and safety
- Reimbursement, market and competition
- Risks, outlook and sources
AI-written from public data and may contain mistakes. Check each fact against its source before relying on it. Not investment, legal, reimbursement or medical advice.
FDA decisions
The newest 6 of 7 decisions filed under this name.
- THORATEC HEARTMATE II LEFT VENTRICULAR ASSIST SYSTEMPMA supplement
P060040-S059 · Decided Jun 23, 2017 · 395 days after receipt · Normal 180 Day Track
Device type: Ventricular (assist) bypass (DSQ) · Cardiology
P060040-S030 · Decided Mar 28, 2014 · 179 days after receipt · Normal 180 Day Track
Device type: Ventricular (assist) bypass (DSQ) · Cardiology
- THORATEC HEARTMATE II LVASPMA supplement
P060040-S015 · Decided Jun 5, 2012 · 113 days after receipt · Normal 180 Day Track No User Fee
Device type: Ventricular (assist) bypass (DSQ) · Cardiology
3 more FDA decisions with a free account
Older decisions: P060040
Medicare coverage
National and local coverage documents whose titles match this device or its device type. Payment add-ons (NTAP, pass-through, TCET) and likely codes are covered in the summary above.
No Medicare coverage document has a title matching this device or device type. Many devices are paid under existing codes without one.
Clinical trials
Device studies on ClinicalTrials.gov that name "Thoratec Heartmate II", any status and sponsor, newest update first.
- Thoratec HeartMate II Left Ventricular Assist System (LVAS) for Destination TherapyPivotal-lookingCompleted
Abbott Medical DevicesPublic (ABT)
NCT00121485 · 200 participants · Start Feb 2005 · Primary completion Jun 2009
Device: Left Ventricular Assist System (LVAS) · For: Heart Failure, Congestive; Ventricular Dysfunction; Cardiomyopathies
Sites: Birmingham, Alabama; Phoenix, Arizona; San Diego, California · 47 sites in all
- MOMENTUM 3 IDE Clinical Study ProtocolPivotal-lookingCompleted
Abbott Medical DevicesPublic (ABT)
NCT02224755 · 1,028 participants · Start Sep 2, 2014 · Primary completion Sep 28, 2018
Device: HeartMate 3 LVAS; HeartMate II LVAS · For: Advanced Refractory Left Ventricular Heart Failure
Sites: Little Rock, Arkansas; Beverly Hills, California; La Jolla, California · 69 sites in all
- Thoratec HeartMate II Left Ventricular Assist System (LVAS) for Bridge to Cardiac TransplantationPivotal-lookingCompleted
Abbott Medical DevicesPublic (ABT)
NCT00121472 · 194 participants · Start Mar 2005 · Primary completion Nov 2006
Device: Thoratec HeartMate II Left Ventricular Assist System (LVAS) · For: Heart Failure, Congestive; Ventricular Dysfunction; Cardiomyopathies
Sites: Birmingham, Alabama; Phoenix, Arizona; San Diego, California · 36 sites in all
3 more trials with a free account
Adverse event reports (MAUDE)
Reports received since 2015 naming the brand "Thoratec Heartmate II", and for the whole product code for context.
This brand
21 reports: 3 malfunction, 13 injury, 5 death
Whole product code DSQ
146,258 reports: 55,625 malfunction, 69,145 injury, 21,450 death
Newest reports for this brand
14851257 · Received Jun 29, 2022 · Event dated May 27, 2022
Device type: Ventricular (Assist) Bypass (DSQ)
Device problem as coded: Adverse Event Without Identified Device or Use Problem
Patient problem as coded: Intracranial Hemorrhage; Muscle Weakness/Atrophy; Paresis; Numbness; Thrombosis/Thrombus
- THORATEC HEARTMATE IIMalfunction
12561449 · Received Oct 1, 2021 · Event dated Sep 12, 2021
Device type: Ventricular (Assist) Bypass (DSQ)
Device problem as coded: Pumping Stopped
Patient problem as coded: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available
- THORATEC HEARTMATE II, SYSTEM CONTROLLERMalfunction
12323933 · Received Aug 16, 2021 · Event dated Jun 28, 2021
Device type: Ventricular (Assist) Bypass (DSQ)
Device problem as coded: Electrical /Electronic Property Problem; Pumping Stopped
Patient problem as coded: Insufficient Information
2 more reports with a free account
Recalls
From FDA's recall database. FDA lists each recalled product separately, so one recall can appear several times. A recall is often a correction or a labeling change, not a removal from the market.
Z-0507-2026 · Started Oct 9, 2025 · Posted by FDA Nov 14, 2025
Reason given: Due to potential corrosion issues associated with the Backup Battery cable connector that may cause a Backup Battery Fault Alarm.
Cause as FDA categorized it: Device Design · Device type: Ventricular (Assist) Bypass (DSQ)
Z-0508-2026 · Started Oct 9, 2025 · Posted by FDA Nov 14, 2025
Reason given: Due to potential corrosion issues associated with the Backup Battery cable connector that may cause a Backup Battery Fault Alarm.
Cause as FDA categorized it: Device Design · Device type: Ventricular (Assist) Bypass (DSQ)
Z-2290-2025 · Started Jun 23, 2025 · Posted by FDA Aug 13, 2025
Reason given: Due to misaligned V-Lock feature on the Mobile Power Unit power cords, which prevents the locking mechanism from properly engaging with the Mobile Power Unit and may cause unintended disconnect.
Cause as FDA categorized it: Vendor change control · Device type: Ventricular (Assist) Bypass (DSQ)
15 more recall records with a free account
Published research
The most relevant PubMed records for "Thoratec Heartmate II"[tiab]. The summary above synthesizes these.
- Pump thrombosis in the Thoratec HeartMate II device: An update analysis of the INTERMACS Registry.
Kirklin JK, Naftel DC, Pagani FD, et al. · J Heart Lung Transplant · 2015Multicenter Study, Research Support, N.I.H., Extramural
- Minimally invasive thoratec Heartmate II implantation in the setting of severe thoracic aortic calcification.
Riebandt J, Sandner S, Mahr S, et al. · Ann Thorac Surg · 2013
- Reliability of the Thoratec HeartMate II flow measurements and alarms in the presence of reduced or non-existent flow.
Hall SG, Gardner K, Larson DF, et al. · Perfusion · 2016
- Mechanical circulatory support for destination therapy.
Tozzi P, Hullin R · Swiss Med Wkly · 2016Review
- Thoratec HeartMate II(®) left ventricular assist device implantation in patient with patent ventriculoperitoneal shunt.
Yamane K, Bogar LJ, Tabata S, et al. · Ann Thorac Cardiovasc Surg · 2012Case Reports
- Ultraviolet Radiation Affects Thoratec HeartMate II Driveline Mechanical Properties: A Pilot Experiment.
Evans AC, Wright GA, McCandless SP, et al. · ASAIO J · 2015Research Support, Non-U.S. Gov't
- High fidelity computational simulation of thrombus formation in Thoratec HeartMate II continuous flow ventricular assist device.
Wu WT, Yang F, Wu J, et al. · Sci Rep · 2016Research Support, N.I.H., Extramural
- Investigation of the Characteristics of HeartWare HVAD and Thoratec HeartMate II Under Steady and Pulsatile Flow Conditions.
Noor MR, Ho CH, Parker KH, et al. · Artif Organs · 2016
- Low-molecular-weight heparin for anti-coagulation after left ventricular assist device implantation.
Sandner SE, Riebandt J, Haberl T, et al. · J Heart Lung Transplant · 2014Research Support, Non-U.S. Gov't
- Protein C Pathway, Inflammation, and Pump Thrombosis in Patients With Left Ventricular Assist Devices.
Walenga JM, Torres TA, Jeske WP, et al. · Clin Appl Thromb Hemost · 2020
- The Contribution to Hemodynamics Even at Very Low Pump Speeds in the HVAD.
Sunagawa G, Byram N, Karimov JH, et al. · Ann Thorac Surg · 2016
- Current status of left ventricular assist device technology.
Molina EJ, Boyce SW · Semin Thorac Cardiovasc Surg · 2013
Other devices of this type
Also filed under product code DSQ.
- HeartWare® Ventricular Assist SystemMedtronic · PMA 2026
- HeartMate 3 Left Ventricular Assist SystemAbbott Medical · PMA 2026
- HeartWare HVAD SystemMedtronic · PMA 2026
- Thoratec Ventricular Assist Device (Vad)Thoratec Laboratories Corp. · PMA 2013
- HeartMate II Left Ventricular Assist SystemAbbott Medical · PMA 2026
- CentriMag Circulatory Support SystemAbbott · PMA 2025
- EXCOR Pediatric Ventricular Assist DeviceBerlin Heart, Inc. · PMA 2026
- Abiomed Bvs 5000 Bi-Ventricular Support SystemAbiomed Cardiovascular, Inc. · PMA 2003
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.