510(k) device
Advia Ims Lithium Assay
Bayer Healthcare, LLC · Assay, Porphyrin, Spectrophotometry, Lithium (NDW, Class II) · First FDA decision Jun 15, 2005, newest Jun 15, 2005Depression
Last checked: Nov 19, 2026Source: FDA, CMS, ClinicalTrials.gov, PubMed
FDA decisions
1
510(k) pathway
Device trials
0
Naming "Advia Ims"
MAUDE reports
0
Brand "Advia Ims", since 2015
PubMed studies
0
Mentioning "Advia Ims"
AI summary across all sources
Written by AI from the FDA, CMS, ClinicalTrials.gov, MAUDE and PubMed data on this page, plus web searches for payment facts.
Product review deck
A slide deck reviewing Advia Ims Lithium Assay
About ten slides on the technology, clinical evidence, regulatory history and commercialization, built with AI from the data on this page and web research, with sources. Download it as PowerPoint to edit or as PDF to share.
- Executive summary and key facts
- Technology
- Clinical evidence and trials
- Regulatory history and safety
- Reimbursement, market and competition
- Risks, outlook and sources
AI-written from public data and may contain mistakes. Check each fact against its source before relying on it. Not investment, legal, reimbursement or medical advice.
FDA decisions
The newest 1 of 1 decisions filed under this name.
- ADVIA IMS LITHIUM ASSAY510(k)
K050374 · Decided Jun 15, 2005 · 121 days after receipt
Device type: Assay, Porphyrin, Spectrophotometry, Lithium (NDW) · Laboratory Medicine & Pathology
Medicare coverage
National and local coverage documents whose titles match this device or its device type. Payment add-ons (NTAP, pass-through, TCET) and likely codes are covered in the summary above.
No Medicare coverage document has a title matching this device or device type. Many devices are paid under existing codes without one.
Clinical trials
Device studies on ClinicalTrials.gov that name "Advia Ims", any status and sponsor, newest update first.
No registered device study names "Advia Ims".
Adverse event reports (MAUDE)
Reports received since 2015 naming the brand "Advia Ims", and for the whole product code for context.
This brand
0 reports: 0 malfunction, 0 injury, 0 death
Whole product code NDW
7 reports: 7 malfunction, 0 injury, 0 death
Newest reports for this brand
No MAUDE reports name this brand.
Recalls
From FDA's recall database. FDA lists each recalled product separately, so one recall can appear several times. A recall is often a correction or a labeling change, not a removal from the market.
- Atellica CH Lithium_2 (LITH_2), Siemens Material Number 11532401. in vitro diagnostic assayOpen, Classified
Siemens Healthcare Diagnostics, Inc.
Z-0104-2023 · Started Sep 19, 2022 · Posted by FDA Oct 20, 2022
Reason given: Potential for falsely elevated LITH_2 and Li results on the Atellica CH 930 Analyzer. In the worst case, there is a potential for erroneously elevated lithium patient results, which may lead to inappropriate dosage adjustment, potentially affecting treatment efficacy.
Cause as FDA categorized it: Under Investigation by firm · Device type: Assay, Porphyrin, Spectrophotometry, Lithium (NDW)
- Atellica CH Lithium (Li), Siemens Material Number 11097535. in vitro diagnostic assayOpen, Classified
Siemens Healthcare Diagnostics, Inc.
Z-0105-2023 · Started Sep 19, 2022 · Posted by FDA Oct 20, 2022
Reason given: Potential for falsely elevated LITH_2 and Li results on the Atellica CH 930 Analyzer. In the worst case, there is a potential for erroneously elevated lithium patient results, which may lead to inappropriate dosage adjustment, potentially affecting treatment efficacy.
Cause as FDA categorized it: Under Investigation by firm · Device type: Assay, Porphyrin, Spectrophotometry, Lithium (NDW)
- Atellica CH Lithium_2 (LITH_2), Siemens Material Number 11097637Open, Classified
Siemens Healthcare Diagnostics, Inc.
Z-0931-2022 · Started Feb 9, 2022
Reason given: Siemens Healthcare Diagnostics Inc. has confirmed the potential for reagent carryover impacting quality control (QC), patient samples, and calibrator results.
Cause as FDA categorized it: Device Design · Device type: Assay, Porphyrin, Spectrophotometry, Lithium (NDW)
- ADVIA Chemistry CalibratorTerminated
Siemens Healthcare Diagnostics, Inc.
Z-2430-2020 · Started Jun 5, 2020
Reason given: Calibration errors have been observed with the Total and Direct Bilirubin assays when using Chemistry Calibrator lot 534177 for ADVIA Chemistry and lot 534179 for Atellica CH.
Cause as FDA categorized it: Nonconforming Material/Component · Device type: Assay, Porphyrin, Spectrophotometry, Lithium (NDW)
Siemens Healthcare Diagnostics, Inc.
Z-0589-2017 · Started Oct 7, 2016
Reason given: Siemens has confirmed that the DBIL_2 Assigned Calibrator Values (ACV) currently assigned to the affected lots may cause, on average, a positive proportional bias of approximately 41% on patient samples compared to the reference method for Direct Bilirubin measurement.
Cause as FDA categorized it: Under Investigation by firm · Device type: Multi-Analyte Controls, All Kinds (Assayed) (JJY)
Siemens Healthcare Diagnostics
Z-0365-2014 · Started Sep 24, 2013 · Posted by FDA Nov 19, 2013
Reason given: Siemens Healthcare Diagnostics is conducting a field correction for Siemens Chemistry Calibrator Lots 090445B and 090445C on the ADVIA 1200, 1650, 1800, and 2400 Chemistry Systems. The System Specific Values (SSVs) for the Direct Bilirubin Assay (DBIL_2) have been reassigned for these lots. Siemens has determined that...
Cause as FDA categorized it: Under Investigation by firm · Device type: Diazo Colorimetry, Bilirubin (CIG)
Published research
The most relevant PubMed records for "Advia Ims"[tiab]. The summary above synthesizes these.
No PubMed record mentions this device by name.
Other devices of this type
Also filed under product code NDW.
- Diazyme Colorimetric Lithium AssayDiazyme Laboratories, Inc. · 510(k) 2025
- Dimension Vista Lithium Flex Reagent CartridgeSiemens Healthcare Diagnostics · 510(k) 2011
- Cobas LithiumRoche Diagnostics Corp. · 510(k) 2008
- Lithium Micro Volume ElectrodeThermo Electron OY · 510(k) 2007
- Sentinel Lithium AssaySENTINEL CH. SpA · 510(k) 2007
- Lithium Regent Model TR66056 / Lithium Standard TR66901Trace America, Inc. · 510(k) 2001
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.